Test | Test Method | Requirement |
Operating temperature | UL 224 | -50 to+125 ℃ |
Tensile strength | ASTM D 2671 | ≥14 Mpa |
Elongation at break | ASTM D 2671 | >400% |
Elongation at break after heat aging | ASTM D 2671 158℃/168hrs | ≥300% |
Longitudinal shrinkage | UL 224 | 0±5% |
Partial wall rate | ASTM D 2671 | <30% |
Flame retardancy | VW-1 | Pass |
Volume resistivity | IEC 93 | >1014Ω.m |
Copper stability | UL224 | Pass |
Type |
Application Diameter Range(mm) |
Expanded(mm) |
Recovered(mm) |
|
D(min) | d(max) | W(min) | ||
RSG-15/5 | 4.5-8 | 15 | 5 | 1.5 |
RSG-20/8 | 6.5-14 | 20 | 8 | 1.8 |
RSG-28/10 | 12-18 | 28 | 10 | 1.8 |
RSG-35/14 | 17-27 | 35 | 14 | 2 |
WRSG10-28/10 | 6.5-14 | 28 | 10 | 2.2 |
WRSG10-34/14 | 17-27 | 34 | 14 | 2.3 |
WRSG10-40/18 | 17-30 | 40 | 18 | 2.5 |
WRSG10-50/20 | 17-35 | 50 | 20 | 2.5 |
WRSG35-50/20 | 17-35 | 50 | 20 | 3 |
WRSG35-60/22 | 21-45 | 60 | 22 | 3 |
WRSG35-70/25 | 24-52 | 70 | 25 | 3 |